Evolution of Pipework

In a constantly progressing society, the industry has had to evolve alongside it to meet the ever changing requirements.  It’s had to look for better ways to design its pipework to make sure that systems can always be optimised and needs are always met.  What is the next step, though, in this evolution, and can it really ensure that systems are easier to use, design, implement and maintain?  Martin Lowe.

 

As with many things in life, pipe layouts have had to evolve to meet the requirements for heating and cooling. Going back many years ago, the first attempt to distribute water through a building was with a one pipe systems, with its very large boilers, large pipework and large radiators, and they took days to warm up.  Using convection currents and relying on water density for circulation was inefficient, costly and depended on predicting the weather three days in advance.

 

Once effective water flow to terminal devices was established, temperature control was required to avoid over-heating and Thermostatic Radiator valves were introduced. The introduction of forced water circulation meant boilers could reduce their water content and pipework developed into two pipes – a flow and return.

 

The two pipe system eased the design and sizing of water distribution system. But evenly distributing the flow to each terminal unit then became a problem; and then further methods needed to be introduced to simplify the commissioning process. A further system was then developed to ease the amount of balancing required in a system, and this was the reverse return system.

 

As we’ve gone through time, there has had to be an evolution of pipework layouts to ensure that the needs of a building and the system can be met, and it’s this constant innovation which has been vital to keep our systems optimised.        

 

Rules

When designing a system we are given certain rules that will deliver a particular accepted solution. Flow rates, pressure drops and pipework size are all taken into consideration at an early stage; then there are further rules regarding installation, cleaning and balancing, and then finally comes best practice, which helps us to avoid simple problems of air, circulation and reductions in flow.

 

The rules are the guidelines which help us to create systems in the best possible way and it’s what, as an industry, we know best and has been tried and tested.  However, what if the fundamental rules of pipe layout changed, and there was no designated direction of flow?

 

Imagine if there is a flow or feed circuit that is pressurised and there is a return circuit at a lower pressure, but flow direction within the flow and return pipework is not predetermined by design but more determined by demand.  Flow can find its own way to supply a unit depending on which routes are available. Thinking in terms of flow direction is actually confusing, and it’s far easier to think more in terms of a pressurised flow returning water through terminal units to a lower pressure return.

 

A circuit such as this is called the Thermal Grid.

 

The Thermal Grid

The impact of computers and their need for constant cooling brought a new challenge to how pipework was laid out.  The n+1 cooling unit was developed and required a ring main solution to allow any cooling unit dual flow supply.

 

The Thermal Grid is just a further extension of the ring main developed for constant cooling to down flow units.   The difference is the way the water is controlled between the flow pipework system and the return pipework. By electronically measuring the flow and having no limitation on the valve’s opening position, the valve can operate at full stroke giving minimum resistance and maximum control. There only has to be enough pressure between the flow and return to overcome the coil and valve resistance. Having the opportunity to measure the flow and the flow requirement allows the pump to work at the lowest setting to match the design requirements of the system at that time.   

 

The control of flow is accurately determined by a flow measuring device that electronically measures the flow and relays that information back to a controller. The controller determines if full design load, part load or no load is required. The water feeding the terminal unit may come from a conventional flow pipe, it equally might come from two directions, some might come from the conventional flow pipe, and other flow might return down the flow pipe fed by extra pipework installed to facilitate this function.

 

Evolution

We’ve seen many changes over the years, and the Thermal Grid is the next obvious step in the pipework evolution.  It helps to overcome many challenges and makes the system easier to control and saves energy.  It may take may years for the industry to move start to actively use such a system, these new ideas always take time for adoption, but by looking at the way ahead and understanding the benefits on offer, some of the problems we face today could be eradicated completely tomorrow.